How the check works
The check asks you, one after another, the questions an assessor would ask: Does your product have a data connection? Does an exclusion under Art. 2 CRA apply? Do you make it available under your own name? And what is its core function? From the answers, it derives whether the Cyber Resilience Act applies, which product class fits and which conformity assessment procedure follows. The check runs entirely in your browser. No data is transmitted or stored; you can copy the result as text at the end.
When a product falls under the CRA
The scope is defined in Art. 2 and Art. 3 of Regulation (EU) 2024/2847. Covered are products with digital elements that are made available on the Union market and whose intended purpose or reasonably foreseeable use includes a direct or indirect logical or physical data connection to a device or network. Three characteristics are decisive:
- Software or hardware product. This includes devices, firmware, operating systems, applications, apps, libraries and remote data processing solutions that are necessary for the product to function (Art. 3(1) and (2)).
- Data connection. Ethernet, fieldbus, Wi-Fi, Bluetooth, USB, cellular or any interface over which data is exchanged. "Indirect" means that a sensor that communicates only via a gateway is also covered.
- Commercial supply. The product is made available on the Union market in the course of a commercial activity, whether in return for payment or free of charge if a commercial purpose is pursued.
Typical examples from our target group: controllers, drives, industrial PCs, sensors with IO-Link, HMI panels, gateways, remote maintenance solutions, configuration software, spare parts with firmware, apps for operating devices, cloud backends for connected devices. Anyone who makes such products available under their own name is a manufacturer under Art. 13, even if they buy in the hardware (Art. 21). Importers (Art. 19) and distributors (Art. 20) have their own, lesser obligations.
Exclusions
Art. 2(2) to (8) excludes products that are already subject to cybersecurity requirements under other EU legal acts or that lie outside internal market law:
| Exclusion | Legal basis | Note |
|---|---|---|
| Medical devices and in vitro diagnostics | Regulations (EU) 2017/745 and 2017/746 | Fully excluded; cybersecurity follows from the MDR and MDCG guidance. |
| Motor vehicles and vehicle systems with type approval | Regulation (EU) 2019/2144 | Excluded to the extent that type approval applies (UN R155/R156). Retrofit products and workshop software outside type approval remain covered. |
| Civil aviation | Regulation (EU) 2018/1139 | Excluded for products subject to EASA certification. |
| Marine equipment | Directive 2014/90/EU | Excluded. |
| Products exclusively for national security and defence | Art. 2(7) | Including products developed specifically for processing classified information. |
| Non-commercial open-source software | Art. 2 and recitals | Free software outside a commercial activity is not covered. Anyone who integrates it into a commercial product bears responsibility for the product (Art. 13(5)). Open-source software stewards are subject to a light regime (Art. 24). |
Not excluded: products for in-house use that are later sold after all; industrial products for closed networks; products "without internet" that nevertheless have a local interface. The data connection does not have to lead to the internet for the CRA to apply. For devices in OT environments, this is the most common misjudgement.
What the result means
The check assigns your product to one of the four classes under Art. 32. The conformity route follows from that:
| Result | Conformity route | What you should do now |
|---|---|---|
| Not in scope | No CRA obligations | Document the reasoning, reassess when the product changes. Check whether your company falls under NIS-2 as an operator. |
| Default product | Self-assessment, module A | Risk assessment, Annex I requirements, technical documentation, EU declaration of conformity, CE marking by 11 December 2027. |
| Important product, class I | Module A only with full application of harmonised standards, otherwise module B+C or H with a notified body | Since no standard has been cited as of October 2026: approach an assessment body and build documentation that is ready for assessment. |
| Important product, class II | Module B+C or H with a notified body | Engage an assessment body early; include assessment duration and waiting time in release planning. |
| Critical product | As class II, later European certification under the CSA | Monitor delegated acts; prepare for the certification scheme. |
Regardless of the class, the reporting obligation under Art. 14 has applied since 11 September 2026 to all products on the market. The complete dates are in the CRA timeline, and the details on classes and modules on the page on CRA product classes.
The check is an initial assessment, not legal advice. It works with your answers and the categories in Annexes III and IV. Borderline cases, such as devices with several core functions, products at the interface with the Machinery Regulation or the Radio Equipment Directive, or software with optional connectivity, require a case-by-case review against the Commission's guidelines. Responsibility for the classification remains with the manufacturer.
Next steps
If the check shows a product in scope, read next which requirements from Annex I are coming your way and how much time remains until 11 December 2027. In our CRA consulting, we review your classification for the entire portfolio, clarify borderline cases with reasoning for the technical documentation and prepare the gap analysis as the basis for your implementation plan.